Home > Products > Data Center Cooling > Precision Air Conditioner
Precision Air Conditioner
CRC In Row Cooing Unit (Chilled Water) 45U
  • CRC In Row Cooing Unit (Chilled Water) 45U
  • CRC In Row Cooing Unit (Chilled Water) 45U
  • CRC In Row Cooing Unit (Chilled Water) 45U
  • CRC In Row Cooing Unit (Chilled Water) 45U

CRC In Row Cooing Unit (Chilled Water) 45U

In case you do not find the type or model in the website We can customized according to your request.
Contact Now
  • Features
  • Technical Data
  • Application
  • Certification
  • Part List
  • Reference
CRC Row-Based Air Conditioner (Chilled water) is more suitable for scenarios with limited on-site installation (no need to install outdoor units) while maintaining accurate cooling characteristics close to the heat source, helping the continuous development of green data centers.

CRC Row-Based Air Conditioner (Chilled water)

Indoor unit model

CRC0030

CRC0060

Air supply

Front air supply

Performance  parameter

Cooling  capacity(kW)

30

60

Sensible  capacity(kW)

30

60

Rated voltage/HZ

220V1Ph~50Hz

380V3Ph~50Hz

Max. operation current FLA (A)

17.5

13.0

Fan  type

EC centrifugal fan

Fan  QTY

6

2

Circulating air volume(m³/h)

5000

11500

Heating capacity  (kW)

3

6

Humidification (kg /h)

1.5

3

Connecting pipe size(30m)

Water inlet pipe size(mm)

DN25

DN32

Water outlet pipe size(mm)

DN25

DN32

Humidification inlet pipe(Internal thread)

G3/4"

Water  pump  drain  pipe(mm)

ID12

Natural drain pipe(mm)

ID16*OD24

Unit dimension and weight

Dimension-W(mm)

300

600

Dimension-D(mm)

1200

Dimension-H(mm)

2000

Weight(kg)

165

205

Electronic element specification

Air  switch recommended  (A)

40

25

Cable   size(mm²)

6

4

Note:
1.Standard working conditions are indoor return air temperature 37℃, RH 24%,inlet/outlet water temperature 10/15℃.
2. The above table is only part of the parameters, and specific configuration is subject to the nameplate. For more parameters, please contact us.


Application scenarios: small/ medium-sized data centers, modular data centers, cabinet cold/ hot aisle transformation. medium and high thermal density communication equipment and computer rooms, etc.

Country: Indonesia
Application: data center
Cooling capacity: 36.7kW
EER: 3.96
Air volume: 12750m3/h
Refrigerant: R410A
Power supply: 380V/3P/50Hz

Country: Philippines
Application: MRI room in hospital
Cooling capacity: 29.8kW
Electric heating: 11kW
Air volume: 7500m3/h
Refrigerant: R407C
Power supply: 400V/3P/60Hz
Downflow air supply

Country: USA
Application: Data center cooling
Cooling capacity: 18kW
Air volume: 4100m3/h
Refrigerant: R410A
Power supply: 400V/3P/60Hz
Remote control

Country: Tajikistan
Application: data base station
Cooling capacity: 13.1kW
Air volume: 2400m3/h
Refrigerant: R407C
Power supply: 380V/3P/50Hz

Country: China
Application: wind farm
Cooling capacity: 50kW
Air volume: 12000m3/h
Refrigerant: R22
Power supply: 380V/3P/50Hz

 

 


Contact us