Counterflow Closed Loop Type Cooling Tower
Contact Now
- TEL:0086-21-35324169
- FAX:0086-21-35324166
- Email:sales@shenglintec.com
- WhatsApp:0086 13916147965
- Mob:0086 13916147965
The LBH design and structure features
The use of cross-flow cooling method, the water rate is very low.
Large interior space, maintenance is very convenient.
Fully enclosed circulation to prevent clogging caused by debris
Heat exchange using building block stacking method, can be installed and removed layer
No need for sink, small footprint, easy to access
Automatic digital display temperature control, energy saving and environmental protection
Simple operation and low maintenance cost.
Product Description
LBH Series closed-type cooling tower is updated and improved by absorbing the most advanced heat exchange technology at home and abroad, and a kind of effective heat exchanging equipment is developed.
Product Performance
LBH products using the combination of water and air and mixed flow two times heat exchange coil and PVC packing technology, to achieve efficient heat exchange. As the air and spray water flow through the coil, the sprinkler to the maximum extent possible to cover the surface of the coil to ensure that the surface of the coil is completely moist. Compared with the reverse structure of feng shui, it greatly reduces the formation of dry point and scale of the coil wall.
Structural Characteristics
1, high-efficiency spray water circulation system
The use of the latest developed ABS special spray guess, with a large amount of spray, water distribution uniformity, not clogging, and other advantages, reasonable water pipe spray height and nozzle layout can be in the outer wall of the coil tube to form a uniform water film, and avoid wall flow. Spray water circulating system special waterproof scale device, reduce corrosion, increase heat exchange effect. The use of outdoor circulating water pump. Reduce energy consumption and reduce maintenance.
2, high efficiency and low noise fan
Second, high-efficiency and low-noise fan using the National Invention Award for the broad-leaved, large chord length, space-twisted aluminum alloy cooling tower dedicated fan, with high efficiency, small vibration, low noise, energy saving. The fan and the motor adopt the direct-linking type, does not need to decelerate, the maintenance is convenient, the motor uses the outdoor type high temperature resistant sealed motor
3, solid corrosion-resistant tower body
In order to make the closed cooling tower in the harshest environment to maintain normal operation, the structure of the tower body and the water-collecting chassis are all made of stainless steel plate folding, the tower plate and fan fan cylinder using xing corrosion of FRP components, closed cooling tower all connectors are stainless steel materials.
4. Efficient water-collecting device
Using the latest FRP material production of three-dimensional water collector, air resistance is small, high water efficiency, in the cycle of more than 999%. To facilitate the internal maintenance of the cooling tower, the water collector is designed as a detachable type
Model |
Cooling capacity |
Cooling flow |
Working pressure |
Spray pump |
Fan |
Inlet and outlet pipe |
Overall dimension mm |
Weight Kg |
|||||
Kcal/h |
m3/h 5℃ 28WB |
Mpa |
Input power kw |
Flow m3/h |
Input power kw |
Flow m3/h |
L |
W |
H |
Net |
Running |
||
LBN-6T |
30000 |
5 |
0.1 |
0.55 |
20 |
0.55 |
8300 |
DN65 |
2200 |
1000 |
1980 |
350 |
500 |
LBN-10T |
50000 |
10 |
0.1 |
0.55 |
20 |
0.75 |
12500 |
DN65 |
2300 |
1000 |
2000 |
450 |
720 |
LBN-15T |
75000 |
15 |
0.15 |
0.55 |
20 |
0.55x2 |
16600 |
DN65 |
2300 |
1000 |
1980 |
530 |
850 |
LBN-20T |
100000 |
20 |
0.15 |
0.55 |
20 |
0.75x2 |
25000 |
DN65 |
2300 |
1000 |
2000 |
580 |
890 |
LBN-25T |
125000 |
25 |
0.2 |
0.75 |
34 |
0.75x2 |
25000 |
DN80 |
2800 |
1250 |
2200 |
750 |
1520 |
LBN-30T |
150000 |
30 |
0.2 |
0.75 |
34 |
1.1x2 |
31000 |
DN80 |
2800 |
1250 |
2200 |
830 |
1650 |
LBN-40T |
200000 |
40 |
0.2 |
0.75 |
34 |
1.1x2 |
31000 |
DN100 |
2900 |
1250 |
2760 |
960 |
1650 |
LBN-50T |
250000 |
50 |
0.25 |
1.1 |
60 |
1.5x2 |
36000 |
DN100 |
2900 |
1500 |
2760 |
1050 |
2080 |
LBN-60T |
300000 |
60 |
0.25 |
1.1 |
60 |
1.5x2 |
36000 |
DN100 |
3000 |
1750 |
3000 |
1220 |
2260 |
LBN-70T |
350000 |
70 |
0.3 |
1.5 |
87 |
1.1x4 |
50000 |
DN125 |
3200 |
2000 |
3000 |
1350 |
2720 |
LBN-80T |
400000 |
80 |
0.3 |
1.5 |
87 |
1.1x4 |
50000 |
DN125 |
3200 |
2200 |
3000 |
1550 |
2980 |
LBN-100T |
500000 |
100 |
0.3 |
2.2 |
100 |
1.5x4 |
72000 |
DN150 |
3600 |
2200 |
3000 |
1780 |
3080 |
LBN-125T |
625000 |
125 |
0.3 |
2.2 |
100 |
1.5x4 |
72000 |
DN150 |
3600 |
2200 |
3220 |
1980 |
3280 |
LBN-150T |
750000 |
150 |
0.3 |
2.2 |
100 |
2.2x4 |
100000 |
DN150 |
3660 |
2200 |
3380 |
2350 |
3980 |
LBN-180T |
900000 |
180 |
0.3 |
4 |
100 |
5.5x4 |
146000 |
DN150 |
3900 |
2300 |
3420 |
2680 |
4650 |
LBN-200T |
1000000 |
200 |
0.4 |
4 |
100 |
5.5x4 |
146000 |
DN150 |
4800 |
2300 |
3480 |
3180 |
4780 |
LBN-250T |
1250000 |
250 |
0.4 |
2.2x2 |
200 |
7.5x2 |
162000 |
DN200 |
5200 |
2300 |
3680 |
4180 |
5570 |
|
|
|
|
2.2x2 |
|
|
162000 |
DN200 |
5500 |
2300 |
4210 |
4180 |
5570 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2.For medium-frequency quenching workpiece, if quenching liquid cooling
3.For vacuum heating, vacuum sintering, vacuum welding, vacuum melting furnace
4.For cooling of air compressors
5.For central air conditioning
6.For cooling of water-cooled screw machine and plate exchanger
7.For screw machines and other equipment
- 01 Feb,2024Dry Cooler D4-8x910 In Stock Is On Sale! Discount!
- 06 Sep,2023Pad Adiabatic Dry Cooler Trial Operation Before Shipment
- 06 Sep,2023828kW Adiabatic Cooling System Dry Cooler Loading
- 17 Aug,2022Flat Type Dry Cooler Finished For Canada Client
- 06 Sep,20231061kW dry cooler loading for USA client
- 31 Mar,2021Peru client Install Shenglin Adiabatic Dry Cooler At Site