Model |
MS6-E2C |
MS9-E2C |
MS12-E2C |
MS16-E2C |
||
|
Power supply |
Ph-V-Hz |
1Ph/220V/50Hz |
||||
|
Cooling |
Capacity |
BTU |
6,000 |
9,000 |
12,000 |
16,000 |
|
Input power |
W |
430 |
720 |
980 |
1,210 |
|
|
Rated current |
A |
2.0 |
3.3 |
4.5 |
5.5 |
|
|
EER |
|
4.1 |
3.7 |
3.6 |
3.9 |
|
|
Heating |
Capacity |
BTU |
6,500 |
10,000 |
13,300 |
17,700 |
|
Input power |
W |
450 |
770 |
1,000 |
1,270 |
|
|
Rated current |
A |
2.1 |
3.5 |
4.6 |
5.8 |
|
|
COP |
|
4.2 |
3.8 |
3.7 |
4.0 |
|
|
Max.current |
A |
3.0 |
5.3 |
6.8 |
8.2 |
|
|
Sea water flow |
M3/h |
0.42 |
0.64 |
0.85 |
1.15 |
|
|
Indoor air flow |
M3/h |
250 |
630 |
630 |
810 |
|
|
Dehumidification capacity |
L/h |
0.7 |
1.1 |
1.8 |
2.1 |
|
|
Noise level |
dB(A) |
≤45 |
≤50 |
≤50 |
≤54 |
|
|
Dimension(L*W*H) |
mm |
461X265X283 |
602X375X387 |
601X398X388 |
627X400X433 |
|
|
Control box(L*W*H) |
mm |
263X182X95 |
||||
|
Net weight |
Kg |
18 |
27 |
30 |
38 |
|
|
Refrigerant type |
|
R410a |
||||
|
Fan duct size |
mm |
Φ100 |
Φ150 |
|||
|
Sea water pipe |
mm |
G1/2”-16 |
||||
|
Condensed water pipe |
Mm |
G1/2”-19 |
||||
|
Note:A 90 degree turn of the air supply hose will reduce the air volume by more than 25%. When installing, the air pipe should be shortened as much as possible, and the right-angle turn of the air pipe or air duct should be reduced |
||||||
|
Model |
MS24-E2C |
MS32-E2C |
MS36-E2C |
MS30-S1C |
MS36-S1C |
||
|
Power supply |
Ph-V-Hz |
1Ph/220V/50Hz |
3Ph/380V/50Hz |
||||
|
Cooling |
Capacity |
BTU |
24,000 |
32,000 |
36,000 |
30,000 |
36,000 |
|
Input power |
W |
1,720 |
2,400 |
2,760 |
2,420 |
2,620 |
|
|
Rated current |
A |
7.8 |
11 |
12.6 |
4.9 |
5.2 |
|
|
EER |
|
4.1 |
3.9 |
3.8 |
3.6 |
4.0 |
|
|
Heating |
Capacity |
BTU |
27,500 |
38,400 |
43,900 |
36,300 |
44,300 |
|
Input power |
W |
1,920 |
2,830 |
3,300 |
2,720 |
3,120 |
|
|
Rated current |
A |
8.7 |
12.8 |
15 |
5.2 |
5.8 |
|
|
COP |
|
4.2 |
4.0 |
3.9 |
3.9 |
4.2 |
|
|
Max.current |
A |
11.7 |
18 |
20.2 |
5.9 |
6.3 |
|
|
Sea water flow |
M3/h |
1.7 |
2.3 |
2.5 |
2.1 |
2.5 |
|
|
Indoor air flow |
M3/h |
1,150 |
1,800 |
1,800 |
1,850 |
1,850 |
|
|
Dehumidification capacity |
L/h |
3.1 |
4.5 |
4.9 |
4.2 |
4.9 |
|
|
Noise level |
dB(A) |
≤59 |
≤64 |
≤67 |
≤65 |
≤67 |
|
|
Dimension(L*W*H) |
mm |
707X433X488 |
756X481X560 |
762X511X560 |
755X480X560 |
760X510X550 |
|
|
Control box(L*W*H) |
mm |
410X195X115 |
400X195X105 |
||||
|
Net weight |
Kg |
56 |
66 |
88 |
65 |
87 |
|
|
Refrigerant type |
|
R410a |
R22 |
||||
|
Fan duct size |
mm |
Φ150 |
Φ200 |
||||
|
Sea water pipe |
mm |
G3/4”-19 |
G1”-25 |
||||
|
Condensed water pipe |
Mm |
G3/4”-25 |
|||||
|
Note:A 90 degree turn of the air supply hose will reduce the air volume by more than 25%. When installing, the air pipe should be shortened as much as possible, and the right-angle turn of the air pipe or air duct should be reduced |
|||||||

|
Model |
MS6-E2C |
MS9-E2C |
MS12-E2C |
MS16-E2C |
||
|
Power supply |
Ph-V-Hz |
1Ph/220V/50Hz |
||||
|
Cooling |
Capacity |
BTU |
6,000 |
9,000 |
12,000 |
16,000 |
|
Input power |
W |
430 |
720 |
980 |
1,210 |
|
|
Rated current |
A |
2.0 |
3.3 |
4.5 |
5.5 |
|
|
EER |
|
4.1 |
3.7 |
3.6 |
3.9 |
|
|
Heating |
Capacity |
BTU |
6,500 |
10,000 |
13,300 |
17,700 |
|
Input power |
W |
450 |
770 |
1,000 |
1,270 |
|
|
Rated current |
A |
2.1 |
3.5 |
4.6 |
5.8 |
|
|
COP |
|
4.2 |
3.8 |
3.7 |
4.0 |
|
|
Max.current |
A |
3.0 |
5.3 |
6.8 |
8.2 |
|
|
Sea water flow |
M3/h |
0.42 |
0.64 |
0.85 |
1.15 |
|
|
Indoor air flow |
M3/h |
250 |
630 |
630 |
810 |
|
|
Dehumidification capacity |
L/h |
0.7 |
1.1 |
1.8 |
2.1 |
|
|
Noise level |
dB(A) |
≤45 |
≤50 |
≤50 |
≤54 |
|
|
Dimension(L*W*H) |
mm |
461X265X283 |
602X375X387 |
601X398X388 |
627X400X433 |
|
|
Control box(L*W*H) |
mm |
263X182X95 |
||||
|
Net weight |
Kg |
18 |
27 |
30 |
38 |
|
|
Refrigerant type |
|
R410a |
||||
|
Fan duct size |
mm |
Φ100 |
Φ150 |
|||
|
Sea water pipe |
mm |
G1/2”-16 |
||||
|
Condensed water pipe |
Mm |
G1/2”-19 |
||||
|
Note:A 90 degree turn of the air supply hose will reduce the air volume by more than 25%. When installing, the air pipe should be shortened as much as possible, and the right-angle turn of the air pipe or air duct should be reduced |
||||||
|
Model |
MS24-E2C |
MS32-E2C |
MS36-E2C |
MS30-S1C |
MS36-S1C |
||
|
Power supply |
Ph-V-Hz |
1Ph/220V/50Hz |
3Ph/380V/50Hz |
||||
|
Cooling |
Capacity |
BTU |
24,000 |
32,000 |
36,000 |
30,000 |
36,000 |
|
Input power |
W |
1,720 |
2,400 |
2,760 |
2,420 |
2,620 |
|
|
Rated current |
A |
7.8 |
11 |
12.6 |
4.9 |
5.2 |
|
|
EER |
|
4.1 |
3.9 |
3.8 |
3.6 |
4.0 |
|
|
Heating |
Capacity |
BTU |
27,500 |
38,400 |
43,900 |
36,300 |
44,300 |
|
Input power |
W |
1,920 |
2,830 |
3,300 |
2,720 |
3,120 |
|
|
Rated current |
A |
8.7 |
12.8 |
15 |
5.2 |
5.8 |
|
|
COP |
|
4.2 |
4.0 |
3.9 |
3.9 |
4.2 |
|
|
Max.current |
A |
11.7 |
18 |
20.2 |
5.9 |
6.3 |
|
|
Sea water flow |
M3/h |
1.7 |
2.3 |
2.5 |
2.1 |
2.5 |
|
|
Indoor air flow |
M3/h |
1,150 |
1,800 |
1,800 |
1,850 |
1,850 |
|
|
Dehumidification capacity |
L/h |
3.1 |
4.5 |
4.9 |
4.2 |
4.9 |
|
|
Noise level |
dB(A) |
≤59 |
≤64 |
≤67 |
≤65 |
≤67 |
|
|
Dimension(L*W*H) |
mm |
707X433X488 |
756X481X560 |
762X511X560 |
755X480X560 |
760X510X550 |
|
|
Control box(L*W*H) |
mm |
410X195X115 |
400X195X105 |
||||
|
Net weight |
Kg |
56 |
66 |
88 |
65 |
87 |
|
|
Refrigerant type |
|
R410a |
R22 |
||||
|
Fan duct size |
mm |
Φ150 |
Φ200 |
||||
|
Sea water pipe |
mm |
G3/4”-19 |
G1”-25 |
||||
|
Condensed water pipe |
Mm |
G3/4”-25 |
|||||
|
Note:A 90 degree turn of the air supply hose will reduce the air volume by more than 25%. When installing, the air pipe should be shortened as much as possible, and the right-angle turn of the air pipe or air duct should be reduced |
|||||||
- 01 Feb,2024Dry Cooler D4-8x910 In Stock Is On Sale! Discount!
- 06 Sep,2023Pad Adiabatic Dry Cooler Trial Operation Before Shipment
- 06 Sep,2023828kW Adiabatic Cooling System Dry Cooler Loading
- 17 Aug,2022Flat Type Dry Cooler Finished For Canada Client
- 06 Sep,20231061kW dry cooler loading for USA client
- 31 Mar,2021Peru client Install Shenglin Adiabatic Dry Cooler At Site