Ammonia Water Absorption Refrigeration Unit
Contact Now
- TEL:0086-21-35324169
- FAX:0086-21-35324166
- Email:sales@shenglintec.com
- WhatsApp:0086 13916147965
- Mob:0086 13916147965
Product selection advice:
|
Working condition |
Air conditioning (0℃ evaporation) |
Standard (-15℃ evaporation) |
Ice making (-20~-30℃ evaporation) |
|||
|
Heat source and requirements |
Temperature |
Flow / Unit cooling capacity |
Temperature |
Flow / Unit cooling capacity |
Temperature |
Flow / Unit cooling capacity |
|
Saturated Vapor |
≥120℃ |
45kg/h |
≥140℃ |
50kg/h |
≥160℃ |
55kg/h |
|
Hot water |
≥140℃ |
1.5m3/h |
≥160℃ |
1.6m3/h |
≥180℃ |
1.8m3/h |
|
Flue gas |
>200℃ |
1000m3/h |
>220℃ |
1100m3/h |
>240℃ |
1200m3/h |
Note:
- The unit cooling capacity is 10,000 kcal/hour;
- 2. The cooling water inlet temperature is 32℃;
- 3. The heat source flow rate is calculated according to the hot water utilization temperature difference of 15℃ and the flue gas utilization temperature difference of 140℃. The utilization temperature difference and the heat source flow rate can be approximated Proportional increase/decrease
Design parameters:
Ammonia water absorption chiller is a non-standard equipment, users need to provide the following parameters when ordering:
|
Heat source parameters |
|
Steam: pressure, temperature, flow |
|
Hot water: temperature, flow |
|
Exhaust gas: temperature, standard flow rate, source, impurity content |
|
Evaporation temperature |
|
If multiple evaporating temperatures are provided on one unit, please indicate the ammonia flow or cooling capacity required for each evaporating temperature |
|
Cooling water |
|
Primary water inlet unit temperature and flow rate; existing cooling tower processing capacity, inlet and outlet temperatures; |
Note:
- The power supply of the unit is three-phase four-wire 380v, 50Hz, and the specifications of the power line must meet the power distribution requirements of the unit;
- The power line and control line sent to the unit should be laid separately, and the user leads to the unit under the electrical control cabinet for control The company is responsible for the wiring in the cabinet;
- The unit and all electrical equipment are provided by the user with reliable grounding, the grounding resistance is less than 10 ohms;
- The user must provide a site that meets the installation of the unit, and do a good job according to the design requirements.
Reference
|
Refrigeration Unit for Chinese institute of Thermophysics |
350kw refrigeration unit for Chinese steel plant. |
|
|
|
- 31 Mar,2021Peru client Install Shenglin Adiabatic Dry Cooler At Site
- 31 Mar,20212021 China Refrigeration Expo Waiting For You
- 16 Dec,2020Shenglin dry cooler`s installation at local site(solar system
- 27 Feb,2019Non-standard customization condensing unit finished!
- 27 Feb,2019Low temperature chiller commissioning in Malaysia
- 27 Feb,2019Shenglin service team`s commissioning in Jordan