Home > Products > Heat Pump > Heating& Cooling Type
Heating& Cooling Type
DC+EVI Inverter Heating & Cooling Heat Pump
  • DC+EVI Inverter Heating & Cooling Heat Pump
  • DC+EVI Inverter Heating & Cooling Heat Pump
  • DC+EVI Inverter Heating & Cooling Heat Pump
  • DC+EVI Inverter Heating & Cooling Heat Pump

DC+EVI Inverter Heating & Cooling Heat Pump

In case you do not find the type or model in the website We can customized according to your request.
Contact Now
  • Features
  • Technical Data
  • Application
  • Certification
  • Part List
  • Reference
Description:

This series heat pump with advanced DC inverter and EVI technology, can save you 80% heating cost compare with the traditional heating device like gas/fuel boiler and electrical heater. It heats fast and works perfectly with the radiator and floor heater to provide you a comfortable living environment even in very cold winter. It is one of the best heating devices available today.

Features:

Twin rotary compressor with inverter control -DC inverter technology control the heat pump output according to the household`s energy requirements. Low waste of the power.
R410A refrigerant, environmentally friendly and no CO2 emissons.
Intelligent controller and LCD display.
Safelly operation with multi-protections.
Electronic expansion valve allows the accurate refrigerant go through under different workign conditions. So it ensures that the heat pump can work with high efficiency to provide enough cooling/heating capacity in any conditions.
Hydrophilic coating air heat exchanger and SWEP plate heat exchanger all available.
Auto defrosting function.
Convenient for installation and maintenance.


Optional:

Galvanized metal cabinet or stainless steel cabinet.
Refrigerant: R22, R407C and R410A
Only heating function is optional.

DC+EVI inverter heating & cooling heat pump

MODEL

BKFXFC-009SMI

BKFXFC-014SMI

BKFXFC-018SMI

Ambient temp. range

 -35~+43℃

 -35~+43℃

 -35~+43℃

Power supply

/

220V 1N~50Hz

220V 1N~50Hz

220V 1N~50Hz

Electric shock proof grade

/

Class I

Class I

Class I

Protection grade

/

IPX4

IPX4

IPX4

Rated cooling capacity

A7W35

KW/-

7.5/2.81

11.5/2.82

14.5/2.82

Rated heating capacity

A-12W41

KW/-

5.3/2.31

9.1/2.35

11.0/2.35

Heating capacity/COP

A7W45

KW/-

8.8/3.60

14.5/3.56

17.5/3.40

A7W55

KW/-

8.1/2.74

14.2/2.92

16.8/2.70

A2W35

KW/-

7.3/3.45

12.0/3.54

14.0/3.54

A-15W45

KW/-

4.2/1.82

8.1/2.04

9.5/2.0

Compressor

Type

Scroll

Scroll

Scroll

Rated refrigerating input power/current

KW/A

2.6/12.2

4.1/18.6

5.16/23.5

Rated heating input power/current.

KW/A

2.30/11.1

3.87/17.6

4.68/21.2

Max. working current

KW/A

4.40/20

6.6/30

7.5/34

Max. working pressure of heat exchanger

Mpa

4.2

4.2

4.2

Temperature range of refrigeration outlet

5~15

5~15

5~15

Heat outlet temperature range

25~58

25~58

25~58

Water yield

L/h

1300

2000

2500

Refrigerant type/Weight

-/kg

R410a/3.3

R410a/4.4

R410a/4.4

Noise

dB/(A)

≤58

≤59

≤59

Dimension (W×D×H)

mm

1090×435×900

1120×440×1360

1120×440×1360

Net weight

kg

80

150

150

a: Rated cooling conditions: ambient temperature 35°C, inlet water temperature 12°C, outlet water temperature 7°C;
b: Rated heating conditions:environmental dry bulb temperature 7°C, wet bulb temperature 6°C, inlet water temperature 40°C, outlet water temperature 45°C;
c: Rated heating conditions:environmental dry bulb temperature -12°C, wet bulb temperature -14°C, outlet water temperature 41°C;
d: A7W45 Operating conditions: inlet air temperature 7°C, outlet air temperature 45°C.
Due to product improvement, above datas are subject to change without prior notice, please take the nameplate as standard.

Contact us
Product Catalog
Products