Cleanroom & Laboratory Air Conditioning Systems
In case you do not find the type or model in the website
We can customized according to your request.
Contact Now
Contact Now
- TEL:0086-21-35324169
- FAX:0086-21-35324166
- Email:sales@shenglintec.com
- WhatsApp:0086 13916147965
- Mob:0086 13916147965
Unit Function Section
The combined air conditioning unit of the clean operating room can be designed with different air treatment functional sections: fresh return air mixing section, primary filter section, surface cold dehumidification section, heating section, humidification section, secondary return air mixing section, fan section, and current equalization section , Medium-efficiency filter section, sub-high-efficiency filter section, sterilization section, air supply section, host side, etc., through the unit function section to perform one or more treatments on the air to meet the required technical requirements for working conditions and effects
Function section name |
|||
1 |
Mixed section |
7 |
Current sharing section |
2 |
Primary-efficiency filter section |
8 |
Medium-efficiency filter section |
3 |
Coil dehumidification section |
9 |
Sub-high efficiency filter section |
4 |
Heater section |
10 |
Sterilization section |
5 |
Humidification section |
11 |
Wind out section |
6 |
Fan section |
12 |
Host segment |
Features
1. High-strength structure: adopts high-strength cooling bridge aluminum alloy profile frame, beautiful appearance and high strength;
2. No deformation: The inner and outer panels and the insulation layer are foamed at one time, and the foaming density is not less than 48kg/m3, which can ensure that the unit does not deform under the pressure difference between the inside and outside of 2500Pa;
3. Anti-cold bridge: high-strength anti-cold bridge aluminum alloy structure, PA66 heat insulation material, completely solve the frame condensation problem;
4. Low air leakage rate: regardless of positive pressure or negative pressure, the air leakage rate is less than 1% under the pressure difference of 1000 Pa between the inside and outside of the machine;
5. Personalized design: improve non-standard customized designs such as annual refrigeration, low-temperature heating, low-temperature air supply, and compressor frequency conversion, and tailor-made technical solutions for clean projects.
SLZK series clean operating room combined air conditioning unit
The effect of lengthening the connecting pipe of the indoor unit on the cooling capacity (recommended the longest pipe length is 35m)
Table of equivalent lengths of elbows and traps
Note: the equivalent pipe length refers to the sum of the length of the straight pipe section of the pipeline plus the equivalent length of the elbow and the trap
Electrical parameter table of outdoor unit of direct expansion combined air handling unit
Note:
1. The power cord of the unit must be a copper core cable, and the working temperature cannot be greater than its specified value. The recommended wire diameter is to use Google when the operating environment is 40 degrees Celsius.
2. If the length of the power cord is greater than 15 meters, please increase the cross section of the power cord appropriately to avoid accidents caused by overload;
3. The recommended power cord diameter does not consider the auxiliary heater. If the unit is equipped with an auxiliary electric heater, it is necessary to select a copper core cable with a wiring diameter that meets the national standard according to the auxiliary electric heater power to avoid accidents. At the same time, when the actual installation conditions on site are changed, please reduce the capacity according to the specifications of the power cord and circuit breaker provided by the manufacturer.
The effect of lengthening the connecting pipe of the indoor unit on the cooling capacity (recommended the longest pipe length is 35m)
Influencing factors | Cooling capacity correction factor | |||||||||
Equivalent total length of connecting pipe | 5m | 10m | 15m | 25m | 30m | 35m | 40m | 45m | 50m | |
The outdoor unit is higher than the indoor unit | 0m | 1 | 0.99 | 0.97 | 0.93 | 0.91 | 0.89 | 0.87 | 0.85 | 0.83 |
5m | 1 | 0.98 | 0.96 | 0.92 | 0.90 | 0.88 | 0.86 | 0.84 | 0.82 | |
10m | / | 0.97 | 0.95 | 0.91 | 0.89 | 0.87 | 0.85 | 0.83 | 0.81 | |
15m | / | / | 0.94 | 0.90 | 0.88 | 0.86 | 0.84 | 0.82 | 0.80 | |
20m | / | / | / | 0.89 | 0.87 | 0.85 | 0.83 | 0.81 | 0.79 | |
25m | / | / | / | 0.88 | 0.86 | 0.84 | 0.82 | 0.80 | 0.78 | |
Indoor unit is higher than outdoor unit | 0m | 1 | 0.99 | 0.97 | 0.93 | 0.91 | 0.89 | 0.87 | 0.85 | 0.83 |
5m | 1 | 0.99 | 0.97 | 0.93 | 0.91 | 0.89 | 0.87 | 0.85 | 0.83 | |
10m | / | 0.99 | 0.97 | 0.93 | 0.91 | 0.89 | 0.87 | 0.85 | 0.83 | |
15m | / | / | 0.97 | 0.93 | 0.91 | 0.89 | 0.87 | 0.85 | 0.83 | |
20m | / | / | / | 0.93 | 0.91 | 0.89 | 0.87 | 0.85 | 0.83 | |
25m | / | / | / | 0.93 | 0.91 | 0.89 | 0.87 | 0.85 | 0.83 |
Table of equivalent lengths of elbows and traps
Connecting pipe outer diameter mm |
9.52 | 12.7 | 15.88 | 19.05 | 28.6 |
Elbow m | 0.2 | 0.25 | 0.3 | 0.35 | 0.5 |
Oil trap m | 1.4 | 1.8 | 2 | 2.4 | 3.7 |
Electrical parameter table of outdoor unit of direct expansion combined air handling unit
Model | SRF8W | SRF12W | SRF16W | SRF20W | SR22W | SR28W | SR33W | SR36W | SR42W | SR48W | SR50W | SR60W | SR66W | SR84W | SR100W | SR210W | SR280W |
Power supply | 3Ph380 V 50Hz | ||||||||||||||||
Power cable | 3*2.5+1+2.5 | 3*4+2.5+4 | 3*6+2.5+6 | 3*10+2.5+10 | 3*16+4+16 | 3*50+6+50 | 3*70+10+70 |
1. The power cord of the unit must be a copper core cable, and the working temperature cannot be greater than its specified value. The recommended wire diameter is to use Google when the operating environment is 40 degrees Celsius.
2. If the length of the power cord is greater than 15 meters, please increase the cross section of the power cord appropriately to avoid accidents caused by overload;
3. The recommended power cord diameter does not consider the auxiliary heater. If the unit is equipped with an auxiliary electric heater, it is necessary to select a copper core cable with a wiring diameter that meets the national standard according to the auxiliary electric heater power to avoid accidents. At the same time, when the actual installation conditions on site are changed, please reduce the capacity according to the specifications of the power cord and circuit breaker provided by the manufacturer.
The functions of the combined air conditioning unit of the clean operating room are flexibly combined according to the working conditions and technical design requirements, and can meet the needs of air purification and temperature and humidity adjustment systems in all walks of life. This product is widely used in medical treatment, medicine, electronic instruments, precision machinery, and products. The air-conditioning purification projects of enterprises such as, light industry and chemical industry are also suitable for the comfortable centralized air-conditioning projects of large and medium-sized public buildings such as scientific research buildings, hospitals, laboratories, training rooms, exhibition halls, shopping malls, and theaters.
Related Product
+Newsmore
- 26 Jan,2025Happy Chinese New Year!
- 01 Feb,2024Dry Cooler D4-8x910 In Stock Is On Sale! Discount!
- 06 Sep,2023Pad Adiabatic Dry Cooler Trial Operation Before Shipment
- 06 Sep,2023828kW Adiabatic Cooling System Dry Cooler Loading
- 17 Aug,2022Flat Type Dry Cooler Finished For Canada Client
- 06 Sep,20231061kW dry cooler loading for USA client
- 31 Mar,2021Peru client Install Shenglin Adiabatic Dry Cooler At Site