Selection of Constant Temperature and Humidity Series for Air Conditioning in Clean Operating Room.
 
1. There are grade requirements for air purification in the space of the place of use, and the relative temperature and humidity require control accuracy. The clean operating room air-conditioning constant temperature and humidity system can be selected; Setting range: temperature is 18~28℃±1~5℃, relative humidity is 40~70%±3~5%;
 
2. Determine the rated air volume: calculate the circulating air volume per unit time according to the number of air changes in the space to be processed and the volume of the space. The rated air volume of the air conditioning unit in the clean operating room must be greater than the theoretical calculation air volume;
 
3.  Determine the cold, heat and humidity load: calculate the cold, heat and humidity load of the space to be handled according to the relevant indoor and outdoor ambient air parameters, fresh air volume and surrounding structural forms;
 
4. Determine the model
a. When the rated air volume meets the requirements, but the cooling and heating load cannot meet the requirements, the selection should be based on the cooling and heating load.
b. When the rated air volume meets the requirements and the cooling and heating load also meets the requirements, the selection should be based on the air volume.
 
5. Determine the condensation method
a. The air-cooled type is suitable for dry and water-deficient areas. It is convenient to install and widely used. Note that there should be more than 1.5M space around the outdoor unit.
b. The water-cooled type is suitable for occasions with abundant water sources, good water quality, and easy installation of the cooling water system. The cooling water system users should prepare their own.
 
6. Determine the type of air supply structure
a. The front air supply type is suitable for the treatment of medium and small areas in the same room. The unit has a built-in high-efficiency and low-noise fan for easy installation
b. The top air supply method is suitable for medium and large processing spaces. The unit has a built-in high static pressure centrifugal fan, which can directly handle the air supply.
c. Direct air supply by pipe is suitable for large processing space. The unit has a built-in fan, and the user needs to provide an additional air box and return air duct to centrally process the supply air.
 
7. Special requirements can be customized
a. Computer centralized control or remote monitoring;
b. Special working conditions, overseas power supply voltage matching;
c. It can provide a constant temperature and humidity clean unit that exceeds the temperature and humidity requirements of the normal use environment: low temperature type, high temperature type, and low humidity type;
d. All fresh air type: meet the temperature and humidity requirements of all resh air conditions, and run intelligently throughout the operation;
e. Environment-friendly refrigerant type: green environment-friendly refrigerants R410A and R134A can be used;
f. Constant temperature and humidity air-conditioning products for clean operating rooms. Steam heating and humidification are clean constant temperature and humidity air-conditioning units that can be heated and humidified by steam;
g. Heat pump heating type: clean constant temperature and humidity air conditioning products that can be heated by heat pumps
Unit quick selection table(air volume):

Model

Nominal air volume m³/h

Windward area of coil㎡

Wind speed of the coil(m/s)

2.00

2.25

2.50

2.75

3.00

3.25

m³/h

0606

1500

0.16

1152

1296

1440

1584

1728

1872

0706

1800

0.2

1440

1620

1800

1980

2160

2340

0806

2200

0.24

1728

1944

2160

2376

2592

2808

0907

3200

0.35

2520

2835

3150

3465

3780

4095

0908

3800

0.42

3024

3402

3780

4158

4536

4914

1009

5000

0.56

4032

4536

5040

5544

6048

6552

1209

6300

0.7

5040

5670

6300

6930

7560

8190

1210

7200

0.8

5760

6480

7200

7920

8640

9360

1510

9500

1.04

7488

8424

9360

10296

11232

12168

1512

12000

1.3

9360

10530

11700

12870

14040

15210

1515

15000

1.69

12168

13689

15210

16731

18252

19773

1815

18000

2.08

14976

16848

18720

20592

22464

24336

1818

23000

2.56

18432

20736

23040

25344

27648

29952

2118

27000

3.04

21888

24624

27360

30096

32832

35568

2121

32000

3.61

25992

29241

32490

35739

38988

42237

2421

37000

4.18

30096

33858

37620

41382

45144

48906

2721

43000

4.75

34200

38475

42750

47025

51300

55575

2724

50000

5.5

39600

44550

49500

54450

59400

64350

3024

55000

6.16

44352

49896

55440

60984

66528

72072

3027

63000

7

50400

56700

63000

69300

75600

81900

3030

70000

7.84

56448

63504

70560

77616

84672

91728

3627

76000

8.5

61200

68850

76500

84150

91800

99450

3630

85000

9.52

68544

77112

85680

94248

102816

111384

3930

93000

10.36

74592

83916

93240

102564

111888

121212

3933

100000

11.47

82584

92907

103230

113553

123876

134199

3936

110000

12.58

90576

101898

113220

124542

135864

147186


Note: 1. It is recommended to add a water baffle if the wind speed exceeds 2.75m/s.

Unit quick selection table(cooling capacity of coil section under return air condition):

Model

Nominal air volume m³/h

4 rows

6 rows

8 rows

Cooling capacity

Water volume

Cooling capacity

Water volume

Cooling capacity

Water volume

kW

m³/h

kW

m³/h

kW

m³/h

0606

1500

8.2

1.4

10.9

1.87

13.2

2.27

0706

1800

10.2

1.8

13.6

2.34

16.5

2.84

0806

2200

12.6

2.2

16.4

2.82

19.8

3.41

0907

3200

17.8

3.1

23.8

4.09

28.8

4.95

0908

3800

21.5

3.7

28.6

4.92

34.6

5.95

1009

5000

28.7

4.9

38.1

6.55

46.2

7.95

1209

6300

35.8

6.2

47.8

8.22

57.5

9.89

1210

7200

41.1

7.1

54.6

9.39

66.1

11.37

1510

9500

53.3

9.2

70.8

12.18

85.6

14.72

1512

12000

66.7

11.5

88.6

15.24

107.1

18.42

1515

15000

86.6

14.9

115.3

19.83

138.6

23.84

1815

18000

106.5

18.3

141.8

24.39

170.3

29.29

1818

23000

131.2

22.6

172.9

29.74

210.5

36.21

2118

27000

155.8

26.8

206.8

35.57

248.6

42.76

2121

32000

185.1

31.8

245.2

42.17

296.5

51.00

2421

37000

214.2

36.8

285.1

49.04

341.8

58.79

2721

43000

243.3

41.8

323.6

55.66

385.6

66.32

2724

50000

281.5

48.4

374.5

64.41

450.3

77.45

3024

55000

315.7

54.3

419.3

72.12

500.4

86.07

3027

63000

358.6

61.7

476.5

81.96

560.4

96.39

3030

70000

400.5

68.9

534.1

91.87

640.5

110.17

3627

76000

432.6

74.4

578.2

99.45

690.5

118.77

3630

85000

482.5

83.0

645.8

111.08

765.8

131.72

3930

93000

520.6

89.5

702.3

120.80

830.5

142.85

3933

100000

576.1

99.1

778.4

133.88

940.8

161.82

3936

110000

630.6

108.5

850.6

146.30

970.5

166.93

Note:
1. The inlet temperature of chilled water is 7°C, and the outlet temperature is 12°C;
2. Return air condition: inlet air dry bulb temperature 27℃, wet bulb temperature 19.5℃;
3. The above parameters are for reference only. If the working conditions and coil circuit arrangement are changed, the parameters will change.

Unit quick selection table(cooling capacity of coil section under fresh air condition):

Model

Nominal air volume m³/h

4 rows

6 rows

8 rows

Cooling capacity

Water volume

Cooling capacity

Water volume

Cooling capacity

Water volume

kW

m³/h

kW

m³/h

kW

m³/h

0606

1500

18.9

3.3

23.5

4.04

28.1

4.83

0706

1800

23.5

4.0

29.4

5.06

35.1

6.04

0806

2200

28.3

4.9

35.3

6.07

42.2

7.25

0907

3200

41.3

7.1

51.4

8.84

61.5

10.57

0908

3800

49.5

8.5

61.7

10.61

73.8

12.69

1009

5000

66.2

11.4

82.3

14.15

98.4

16.92

1209

6300

82.3

14.2

102.8

17.68

122.9

21.15

1210

7200

94.5

16.3

117.5

20.21

140.5

24.17

1510

9500

122.9

21.1

152.8

26.27

182.7

31.42

1512

12000

153.2

26.4

190.9

32.84

228.3

39.27

1515

15000

195.6

33.6

248.2

42.69

296.8

51.05

1815

18000

245.6

42.2

305.5

52.55

365.3

62.83

1818

23000

302.1

52.0

376.0

64.67

449.6

77.33

2118

27000

358.7

61.7

446.5

76.80

533.9

91.83

2121

32000

426.1

73.3

530.2

91.20

634.0

109.05

2421

37000

492.8

84.8

613.9

105.60

734.1

126.27

2721

43000

560.8

96.5

697.7

120.00

834.2

143.49

2724

50000

648.9

111.6

807.8

138.94

965.9

166.14

3024

55000

727.6

125.1

904.8

155.62

1081.9

186.08

3027

63000

826.4

142.1

1028.1

176.84

1229.4

211.45

3030

70000

924.8

159.1

1151.5

198.06

1376.9

236.83

3627

76000

1005.4

172.9

1248.4

214.73

1492.8

256.76

3630

85000

1124.3

193.4

1398.3

240.50

1672.0

287.58

3930

93000

1200.6

206.5

1514.6

260.51

1812.4

311.73

3933

100000

1320.6

227.1

1671.4

287.48

2010.3

345.77

3936

110000

1450.7

249.5

1825.7

314.02

2186.5

376.08

Note: 
1. The inlet temperature of chilled water is 7℃, and the outlet temperature is 12℃;
2. Fresh air conditions: inlet air dry bulb temperature 35℃, wet bulb temperature 28℃;
3. The above parameters are for reference only. If the working conditions and coil circuit arrangement are changed, the parameters will change.

Unit quick selection table(hot water coil heating capacity):

Model

Nominal air volume m³/h

Return air condition

Fresh air condition

2 rows

3 rows

4 rows

2 rows

3 rows

4 rows

heating capacity

heating capacity

heating capacity

heating capacity

heating capacity

heating capacity

kW

kW

kW

kW

kW

kW

0606

1500

9.4

12.5

14.8

11.1

15.1

18.1

0706

1800

11.8

15.6

18.5

13.9

18.9

22.6

0806

2200

14.1

18.8

22.2

16.7

22.7

27.2

0907

3200

20.6

27.3

32.4

24.3

33.0

39.6

0908

3800

24.7

32.8

38.9

29.1

39.6

47.5

1009

5000

32.9

43.8

51.8

38.9

52.9

63.4

1209

6300

41.1

54.7

64.8

48.6

66.1

79.2

1210

7200

47.0

62.5

74.0

55.5

75.5

90.5

1510

9500

61.1

81.3

96.2

72.2

98.2

117.7

1512

12000

76.4

101.6

120.3

90.2

122.7

147.1

1515

15000

99.3

132.0

156.3

117.2

159.5

191.2

1815

18000

122.2

162.5

192.4

144.3

196.3

235.3

1818

23000

150.4

200.0

236.8

177.6

241.6

289.6

2118

27000

178.6

237.5

281.2

210.9

286.9

343.9

2121

32000

212.1

282.0

333.9

250.4

340.7

408.4

2421

37000

245.6

326.6

386.7

290.0

394.5

472.9

2721

43000

279.1

371.1

439.4

329.5

448.3

537.3

2724

50000

323.1

429.7

508.8

381.6

519.1

622.2

3024

55000

361.9

481.3

569.8

427.4

581.4

696.9

3027

63000

411.3

546.9

647.5

485.6

660.6

791.9

3030

70000

460.6

612.5

725.2

543.9

739.9

886.9

3627

76000

499.4

664.1

786.3

589.7

802.2

961.6

3630

85000

559.3

743.8

880.6

660.5

898.5

1077.0

3930

93000

608.7

809.4

958.3

718.7

977.7

1172.0

3933

100000

673.9

896.1

1061.0

795.7

1082.5

1297.5

3936

110000

739.1

982.8

1163.7

872.7

1187.2

1423.1

Note: 
1. The inlet temperature of hot water is 60°C, and the outlet temperature is 50°C;
2. Return air condition: inlet air dry bulb temperature 15℃; fresh air condition: inlet air dry bulb temperature 7℃;
3. The above parameters are for reference only. If the working conditions and coil circuit arrangement are changed, the parameters will change.
 
Unit quick selection table(hot water coil heating capacity):

Model

Nominal air volume m³/h

One row of steam heating

Two rows of steam heating

Steam pressure

Steam pressure

0.1MPa

0.2MPa

0.3MPa

0.1MPa

0.2MPa

0.3MPa

kW

kW

kW

kW

kW

kW

0606

1500

8.9

10.2

11.1

14.3

16.2

17.6

0706

1800

11.1

12.8

13.9

17.9

20.3

22.0

0806

2200

13.4

15.3

16.7

21.5

24.3

26.4

0907

3200

19.5

22.3

24.3

31.3

35.4

38.5

0908

3800

23.4

26.8

29.1

37.5

42.5

46.2

1009

5000

31.2

35.7

38.9

50.1

56.7

61.6

1209

6300

38.9

44.6

48.6

62.6

70.9

77.0

1210

7200

44.5

51.0

55.5

71.5

81.0

88.0

1510

9500

57.9

66.3

72.2

93.0

105.3

114.4

1512

12000

72.3

82.9

90.2

116.2

131.6

143.0

1515

15000

94.0

107.7

117.2

151.0

171.1

185.9

1815

18000

115.7

132.6

144.3

185.9

210.6

228.8

1818

23000

142.4

163.2

177.6

228.8

259.2

281.6

2118

27000

169.1

193.8

210.9

271.7

307.8

334.4

2121

32000

200.8

230.1

250.4

322.6

365.5

397.1

2421

37000

232.5

266.5

290.0

373.6

423.2

459.8

2721

43000

264.2

302.8

329.5

424.5

480.9

522.5

2724

50000

305.9

350.6

381.6

491.6

556.9

605.0

3024

55000

342.7

392.7

427.4

550.6

623.7

677.6

3027

63000

389.4

446.3

485.6

625.6

708.8

770.0

3030

70000

436.1

499.8

543.9

700.7

793.8

862.4

3627

76000

472.8

541.9

589.7

759.7

860.6

935.0

3630

85000

529.6

606.9

660.5

850.9

963.9

1047.2

3930

93000

576.3

660.5

718.7

925.9

1049.0

1139.6

3933

100000

638.0

731.2

795.7

1025.1

1161.3

1261.7

3936

110000

699.8

802.0

872.7

1124.3

1273.7

1383.8


Note: 
1. Heating conditions, the inlet air dry bulb temperature is 7℃;
2. The structure of the heater is a steel pipe wound around a steel fin;
3. The above parameters are for reference only. If the working conditions and coil circuit arrangement are changed, the parameters will change.
Widely used in the fields of pharmaceuticals, tobacco, medical treatment, biology, electronics, and automobile manufacturing.
 