1. Heat Exchanger Radiator:
Application
Air conditioning: |
||
Tube fin heat exchanger as radiator for split air conditioner: |
Tube fin heat exchanger as radiator for air handling unit: |
Tube fin heat exchanger as radiator for fan coil unit: |
|
|
|
Machinery: |
||
Tube fin heat exchanger as radiator for electrical cabinet: |
Micro-channel heat exchanger as radiator for communication cabinet: |
Plate fin heat exchanger as radiator for wheel loader: |
|
|
|
Plate fin heat exchanger as radiator for generator set: |
Tube fin heat exchanger as radiator for beauty laser equipment: |
Tube fin heat exchanger as radiator for oxygenerator: |
|
|
|
Automobile: |
||
Tube fin heat exchanger as radiator for car: |
Microchannel heat exchanger as radiator for car: |
|
|
|
|
2. Dry Cooler Radiator:
Dry cooler radiators are available in a wide performance range between 10 and 2,000 kW condensing performance. Depending on case of application, you can select between different series. All radiators are available in different noise levels and naturally suitable for outside installation.
Structure Type | Model | Photo | Cooling cpacity (kw) | Air volume (m3/h) | Fan Diameter(mm) | Air discharge direction | Key documents |
---|---|---|---|---|---|---|---|
Plate Type Radiator | SHSL-D1-005-1x350~SD1-649-16x630 |
![]() |
5~649 | 2828~263503 | 350~630 | Vertical | Brochure of SHSL-D1 |
![]() |
Horizontal | ||||||
V Type Radiator | SHSL-D2-148-4X630~SD2-921-20x630 |
![]() |
148~921 | 76459~351663 | 630 | Vertical | Brochure of SHSL-D2 |
Plate Type Radiator | SHSL-D3-042-1X800~SD3-607-12X800 |
![]() |
42~607 | 21454~227449 | 800 | Vertical | Brochure of SHSL-D3 |
V Type Radiator | SHSL-D4-176-4X800~SD4-792-16X800 |
![]() |
176~792 | 21454~227449 | 800 | Vertical | Brochure of SHSL-D4 |
Application
Case 1: used in chemical plant. | Case 2: used in chemical plant. Refrigerant: ethylic acid(flow: 372 ton/h) | Case 3: used in communication station as air conditioner outdoor unit in China. | Case 4: used in communication station as air conditioner outdoor unit |
![]() |
![]() |
![]() |
![]() |
Case 5: used in garbage gisposal incinerator. Refrigerant: steam(flow: 69ton/h) | Case 6: used in a power plant in Iraq | Case 7: used in ore yard in Russia. | Case 8: special designed to match the fruit and vegetable freezer for Singapore client. |
![]() |
![]() |
![]() |
![]() |
Radiator Dry Cooler, Industrial Radiator, Remote Radiator.
- 16 Dec,2020Shenglin dry cooler`s installation at local site(solar system
- 11 Apr,2020Return to work
- 17 Jul,2019INVITATION-Bangkok RHVAC 2019
- 27 Feb,2019Non-standard customization condensing unit finished!
- 27 Feb,2019Low temperature chiller commissioning in Malaysia
- 27 Feb,2019Shenglin service team`s commissioning in Jordan