Home > Products > BTC Mining Cooling
BTC Mining Cooling
Air Conditioner For  Energy Storage Container
  • Air Conditioner For  Energy Storage Container
  • Air Conditioner For  Energy Storage Container
  • Air Conditioner For  Energy Storage Container
  • Air Conditioner For  Energy Storage Container

Air Conditioner For Energy Storage Container

In case you do not find the type or model in the website We can customized according to your request.
Contact Now
  • Features
  • Technical Data
  • Application
  • Certification
  • Part List
  • Reference
High efficiency

Built-in reliability

Rugged Construction

Wall-mounted air conditioning unit performance parameter table

Model: GT-HFM-

35

45

55

70

Cooling capacity

kW

35.0 

45.0 

55.0 

70.0 

Air volume

m3/h

8925

11475

14025

17850

External static pressure

Pa

150

200

200

200

Total inpout power

KW

26.7

32.3

43.55

51.75

Supply air fan

Type

EC fan

Qty

Power

1.65*2

2.6*2

1.65*3

1.65*4

Electric heating

Type

Stainless steel pipe

kW

9.0 

9.0 

18.0 

18.0 

Unit noise

dB(A)

77

80

82

84

Temperature control

18~28

18~28

18~28

18~28

Power supply

3N-380V-50Hz

3N-380V-50Hz

3N-380V-50Hz

3N-380V-50Hz

Compressor

Type

Fully enclosed scroll

Fully enclosed scroll

Fully enclosed scroll

Fully enclosed scroll

Qty

2

2

3

3

Power

6+7.5

7.5+9.5

7.5+7.5+4.5

9+9+7.5

Refrigerant

Type

R134a

Way

Externally balanced thermal expansion valve/electronic expansion valve

Condensing fan

Type

Axial fan

Qty

2

2

2

3

Power

0.45*2

0.55*2

0.55*2

0.55*3

Drain pipe

DN25

DN25

DN25

DN25

Dimensions

L(mm)

1620

2120

2620

3020

W(mm)

900

900

1000

1100

H(mm)

2450

2450

2550

2550

Unit weight

kg

850

1050

1200

1700


Note:
1. Cooling conditions: indoor dry bulb/wet bulb temperature 27/19℃; outdoor dry bulb/wet bulb temperature 35/24℃;
2. Heating conditions: indoor dry bulb/wet bulb temperature 20/—℃; outdoor dry bulb/wet bulb temperature 7/6℃;
3. The air volume, static pressure, power, etc. in the table are standard parameters, which can be designed according to customer requirements, and the input power of the whole machine may change;
4. The noise is measured at a height of 1.2m and 2m from the front of the unit when cooling under standard air volume;
5. Inverter compressor system can be used to achieve more accurate capacity control;
6. Heaters, humidifiers, hot and cold water coils are optional parts, and specific forms can be configured according to customer site requirements.
 

Applications including energy storage containers, telecommunications shelters, classrooms, relocatable offices and control rooms.

Contact us