B
(mm)
B1
(mm)
D
(mm)
D1
(mm)
A
(mm)
Volume
(L)
area
(m²)
weight
(kg)
distributor
capacity
(KW)
391.4
397.2
397.2
163.7
11+2.3n
0.16
0.11
6.5+0.42n
Q
60~200
391.4
397.2
397.2
163.7
11+2.2n
0.16
0.11
6.5+0.33n
Q
50~250
599
628
628
232
13+2.85n
0.4
0.21
13+0.82n
Q
150~450
 
 
Mold
clamp size
max width
max height
max length
interface size
max number of chip
max flow
BB30H
N(2.4+X)
180
490
680
32
90
13
BB60B
N(2.0+X)
320
930
1200
60
250
36
BB60H
N(3.0+X)
320
930
1200
60
203
36
BB65T
N(4.0+X)
410
700
1400
65
130
72
BB100B
N(3.95+X)
470
1069
1600
100
278
140
BB100H
N(3.95+X)
470
1069
1600
100
180
140
BB150B
N(2.5+X)
610
1815
3000
150
600
360
BB150T
N(3.95+X)
610
1815
3000
150
450
360
BB200T
N(2.5+X)
800
1435
2700
295
285
520
BB200H
N(4.0+X)
780
2150
3000
200
420
600
BB250B
N(2.5+X)
920
2900
3300
250
500
900
BB300B
N(3.5+X)
1100
2415
3360
300
300
997
 

 (1) Between the heat exchanger will produce the two-way medium mixing serious consequences occasions: ① corrosive and toxic occasions. Fluid tube side and shell side does not produce corrosive or toxic when not in contact with the phenomenon, but the tube, the shell of the two-phase fluid mixture may cause severe corrosion or poisoning. ② hazardous areas. When the tube, the shell of the two fluids are mixed (contact), it will cause fire and explosion. ③ equipment causing dirt occasions. When the tube, the shell of the two fluids are mixed, such as the formation of a resinous substance or polymer. ④ adverse chemical reaction of the occasion. In the tube, the shell of the two fluids after contact, so that a chemical reaction is limited or no response or adverse reactions, contamination of the product, the product quality.