Home > Products > Chiller > Chemical Industry
Chemical Industry
Air Cooled Low Temperature Chiller -5 Degree
  • Air Cooled Low Temperature Chiller -5 Degree
  • Air Cooled Low Temperature Chiller -5 Degree
  • Air Cooled Low Temperature Chiller -5 Degree
  • Air Cooled Low Temperature Chiller -5 Degree

Air Cooled Low Temperature Chiller -5 Degree

In case you do not find the type or model in the website We can customized according to your request.
Contact Now
  • Features
  • Technical Data
  • Application
  • Certification
  • Part List
  • Reference
Features
1. Compressor: adopt international brand semi closed 5:6 non symmetrical double screw type air cooled special type compressor.
2. Heat exchanger: evaporator use high efficient shell and tube heat exchanger, condenser use high efficiency copper pipe+hydrophilic aluminum fin; with high pressure, high heat transfer efficiency, maintenance free, long service life, etc.;
3. Control system: using SIEMENS control system, advanced PLC control technology, can accept the programming, perfect communication function;
4. The electrical system: SIEMENS, Schneider and other national brands of electrical components, waterproof type control cabinet;
5. Man-machine interface: Chinese and  English man-machine interface, touch type liquid crystal display operation, simple procedures, one key to start, automatic operation;
6. Chiller maintenance: chiller adopts integral design, compact structure, simple, strong corrosion resistance, with waterproof control cabinet, to ensure that the unit can be placed outside the long-term is not easy to fade, corrosion.
7. The choice of environmental protection type R407C or R134a refrigerant.

 


Air-cooled screw unit -5℃(Single compressor)

 Model

Unit

SLA-

50.1c

69.1c

93.1c

101.1c

125.1c

135.1c

160.1c

170.1c

185.1c

202.1c

Cooling capacity

Btu

170600.00

235428.00

317316.00

344612.00

426500.00

460620.00

545920.00

580040.00

631220.00

689224.00

RT

14.20

19.60

26.42

28.69

35.51

38.35

45.45

48.30

52.56

57.39

Kw

50.00

69.00

93.00

101.00

125.00

135.00

160.00

170.00

185.00

202.00

×104Kcal/h

4.30

5.90

8.00

8.70

10.80

11.60

13.80

14.60

15.90

17.40

Control mode

PLC fully automatic control

power source

380V/3N/50Hz

 Total Power

KW

26.80

35.60

44.90

49.70

62.50

66.60

74.20

78.90

86.00

94.10

 Total Current

A

46.90

62.30

78.60

87.00

109.40

116.60

129.90

138.10

150.50

164.70

         Compressor

 Type

5-6 asymmetric semi-hermetic screw compressor

Startup type

Y-△

 Energy regulation

0-33-66-100%

0-25%-50%-75%-100%

Input power

KW

25.00

32.90

41.30

45.30

55.90

60.00

67.60

71.10

78.20

85.30

Operation
Current

A

43.80

57.60

72.30

79.30

97.80

105.00

118.30

124.40

136.90

149.30

Condenser

Type

High efficiency copper dry type shell-and-tube heat exchanger

 Water pipe connection

m³/h

21500.00

29700.00

40000.00

43400.00

53800.00

58100.00

68800.00

73100.00

79600.00

86900.00

 Cooling Water Flow

 

6‘

6’

8‘

8’

6‘

6‘

6’

6‘

6’

8‘

Water pressure

KW

0.30

0.45

0.45

0.55

1.10

1.10

1.10

1.30

1.30

1.10

   Evaporator

 Type

 Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger

 Water pipe connection

m³/h

8.60

11.90

16.00

17.40

21.50

23.20

27.50

29.30

31.80

34.80

 Chilled water Flow

DN

50.00

50.00

65.00

65.00

65.00

80.00

80.00

80.00

80.00

100.00

Water pressure

kpa

44.00

45.00

47.00

49.00

50.00

50.00

50.00

50.00

52.00

55.00

Refrigerant

    Type

 

R22

Filling quantity

kg

18.00

26.00

34.00

37.00

46.00

50.00

59.00

63.00

68.00

75.00

Safety protection

high and low pressure protection,overload protection,over temperature protection,phase sequence   protection,etc.

Dimensions (L*W*H)

 Length

mm

2450

2750

2950

3200

3200

3200

3200

3200

3550

4400

Width

mm

1350

1400

1400

1500

2200

2200

2200

2200

2200

2200

 High

mm

2020

2020

2200

2200

2300

2300

2300

2350

2350

2350

Net Weight

kg

1850

2000

2400

2600

2800

2950

3100

3300

3550

3750

Operating weight

kg

2000

2200

2600

2900

3100

3180

3350

3600

3900

3750



 Model

UNIT

SLA-

220.1c

255.1c

270.1c

295.1c

320.1c

335.1c

380.1c

425.1c

455.1c

505.1c

Cooling capacity

Btu

750640.00

870060.00

921240.00

1006540.00

1091840.00

1143020.00

1296560.00

1450100.00

1552460.00

1723060.00

RT

62.50

72.44

19.89

83.81

90.91

95.17

107.95

120.74

129.26

143.47

Kw

220.00

255.00

270.00

295.00

320.00

335.00

380.00

425.00

455.00

505.00

×104Kcal/h

18.90

22.00

23.00

25.00

28.00

29.00

33.00

37.00

39.00

43.00

Operation mode

PLC fully automatic control

Power

380V/3N/50Hz

 Total Power

KW

105.30

122.20

129.40

141.10

153.70

158.10

182.60

200.60

215.50

235.40

 Total Current

A

184.30

213.90

226.50

246.90

269.00

276.70

319.60

351.10

377.00

412.00

         Compressor

Type

5-6 asymmetric semi-hermetic screw compressor

startup type

Y-△

 Energy regulation

0-25-50-75-100%

Input power

KW

94.90

110.20

116.40

126.10

135.70

140.10

164.60

182.60

193.90

213.80

Operation Current

A

166.10

192.90

203.70

220.70

237.50

245.20

288.10

320.00

339.00

374.00

Condenser

 Type

High efficiency copper dry type shell-and-tube heat exchanger

Air volume

m³/h

94600.00

109700.00

116100.00

126900.00

137600.00

144100.00

163400.00

182800.00

195700.00

217200.00

Condensation and axial-flow fan

Qty

 

8‘

8’

10‘

10’

10‘

10‘

12’

12‘

12’

12‘

unit power

KW

1.30

1.50

1.30

1.50

1.80

1.80

1.50

1..5

1.80

1.80

  Evaporator

 Type

  Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger

Cooling Water Flow

m³/h

37.90

43.90

46.50

50.80

55.10

57.70

65.40

73.10

78.30

86.90

Water pipe connection

DN

100.00

100.00

100.00

125.00

125.00

125.00

125.00

125.00

125.00

125.00

Water pressure

kpa

57.00

59.00

63.00

65.00

67.00

69.00

71.00

72.00

74.00

75.00

Refrigerant

 Type

R22

Filling quantity

kg

81.00

94.00

100.00

109.00

118.00

124.00

140.00

157.00

168.00

187.00

Safety protection

high and low pressure protection,overload protection,over temperature protection,phase sequence protection,etc.

Dimensions (L*W*H)

 Length

mm

3550

4400

4400

4400

4400

4400

5600

5600

5800

5800

 Width

mm

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

  High

mm

2350

2350

2500

2500

2500

2500

2560

2560

2560

2560

Unit net weight

kg

3950

4400

4600

5100

5500

5650

5780

5850

6000

6250

       Operating weight

kg

4300

4800

5100

5600

6100

6200

6330

6400

6600

6900


 Note:
1.Chilled water inlet temperature 0℃, chilled water outlet temperature -5 ℃; cooling water inlet temperature of 30 ℃, cooling water outlet temperature of 35 ℃;   
2.Temperature conditions: chilled water outlet temperature range 5 ℃ -15 ℃, cooling water inlet temperature range 19 ℃ -33 ℃;                                                                                           3.Safe operating range : chilled water inlet temperature 9℃-20℃;                                                                                                                                                                                     4.The using compressor is closed turbine  imported from Europe and the United States , superior performance, strong ability of anti-effusion;                                                                         5.Nominal operating conditions in the evaporator and condenser water side fouling factor of 0.018m² ℃ / kw, condenser water side fouling factor of 0.044 m² ℃ / kw;                                         6. Water side of the evaporator and condenser, designed to withstand a pressure of 1.0MPa;                                                                                                                                             7. The actual head of Host is that the pump head minus head losses within the host;                                                                                                                                                       8. In addition to the specifications and requirements, we can provide non-standard products according to customer requirements.
Application: It is mainly used to cool down the chemical reaction kettle (chemical heat exchanger), and take away the huge heat produced by chemical reaction in time so as to achieve the purpose of cooling (cooling), so as to improve the product quality and production efficiency.

No.

Name

Brand

Original

1

Compressor

COPELAND

USA

2

Controller

BANGPU

China

AC contactor

LG

Korea

Thermal relay

LG

Korea

3

Heat exchanger

     Shenglin

China

Fan

MAER

China

Expansion valve

EMERSON

USA

DANFOSS

Denmark

High and low pressure gauge

HONGSEN

China

Flow switch

KAOBO

China

Water pump

SOUTH

China

Country: Bolivia
Chiller type: water cooled
Cooling capacity: 130kW
Cooling medium: R407C
Supply power: 3P-380V-50Hz
Compressor brand: COPELAND
Compressor type: scroll
Water outlet tem.: 7℃

Country: Philippines
Chiller type: air cooled
Cooling capacity: 130kW
Cooling medium: R22
Supply power: 3P-380V-60Hz
Compressor brand: COPELAND
Compressor type: scroll
Water outlet tem.: 7℃

Country: Malaysia
Chiller type: water cooled
Cooling capacity: 175kW
Cooling medium: R22
Supply power: 3P-380V-50Hz
Compressor brand: HANBELL
Compressor type: screw
Water outlet tem.: 7℃

Country: UAE
Chiller type: air cooled
Cooling capacity: 41kW
Cooling medium: R22
Supply power: 3P-380V-50Hz
Compressor brand: COPELAND
Compressor type: scroll
Water outlet tem.: 7℃

 

 


 


 



Contact us
Product Catalog
Products